Hi,

On 11/17/23 2:46 AM, Zhijie Hou (Fujitsu) wrote:
> On Tuesday, November 14, 2023 10:27 PM Drouvot, Bertrand <bertranddrouvot.pg@gmail.com> wrote:
>> On 11/13/23 2:57 PM, Zhijie Hou (Fujitsu) wrote:
>>> On Friday, November 10, 2023 4:16 PM Drouvot, Bertrand
>> <bertranddrouvot.pg@gmail.com> wrote:
>>>> Yeah good point, agree to just error out in all the case then (if we
>>>> discard the sync_ reserved wording proposal, which seems to be the
>>>> case as probably not worth the extra work).
>>>
>>> Thanks for the discussion!
>>>
>>> Here is the V33 patch set which includes the following changes:
>>
>> Thanks for working on it!
>>
>>>
>>> 1) Drop slots with state 'i' in promotion flow after we shut down WalReceiver.
>>
>> @@ -3557,10 +3558,15 @@ WaitForWALToBecomeAvailable(XLogRecPtr
>> RecPtr, bool randAccess,
>>                        * this only after failure, so when you promote, we still
>>                        * finish replaying as much as we can from archive and
>>                        * pg_wal before failover.
>> +                    *
>> +                    * Drop the slots for which sync is initiated but not yet
>> +                    * completed i.e. they are still waiting for the primary
>> +                    * server to catch up.
>>                        */
>>                       if (StandbyMode && CheckForStandbyTrigger())
>>                       {
>>                           XLogShutdownWalRcv();
>> +                       slotsync_drop_initiated_slots();
>>                           return XLREAD_FAIL;
>>                       }
>>
>> I had a closer look and it seems this is not located at the right place.
>>
>> Indeed, it's added here:
>>
>> switch (currentSource)
>> {
>>     case XLOG_FROM_ARCHIVE:
>>     case XLOG_FROM_PG_WAL:
>>
>> While in our case we are in
>>
>>     case XLOG_FROM_STREAM:
>>
>> So I think we should move slotsync_drop_initiated_slots() in the
>> XLOG_FROM_STREAM case. Maybe before shutting down the sync slot worker?
>> (the TODO item number 2 you mentioned up-thread)
> 
> Thanks for the comment.
> 
> I feel the WaitForWALToBecomeAvailable may not be the best place to shutdown
> slotsync worker and drop slots. There could be other reasons(other than
> promotion) as mentioned in comments in case XLOG_FROM_STREAM to reach the code
> there. I thought if the intention is to stop slotsync workers on promotion,
> maybe FinishWalRecovery() is a better place to do it as it's indicating the end
> of recovery and XLogShutdownWalRcv is also called in it.

I can see that slotsync_drop_initiated_slots() has been moved in FinishWalRecovery()
in v35. That looks ok.
> 
> And I feel we'd better drop the slots after shutting down the slotsync workers,
> because otherwise the slotsync workers could create the dropped slot again in
> rare cases.

Yeah, agree and I can see that it's done that way in v35.

Regards,

-- 
Bertrand Drouvot
PostgreSQL Contributors Team
RDS Open Source Databases
Amazon Web Services: https://aws.amazon.com



pgsql-hackers by date:

Previous
From: Amit Kapila
Date:
Subject: Re: Synchronizing slots from primary to standby
Next
From: Amul Sul
Date:
Subject: Re: ALTER COLUMN ... SET EXPRESSION to alter stored generated column's expression