On Thu, Feb 22, 2024 at 4:35 PM Bertrand Drouvot
<bertranddrouvot.pg@gmail.com> wrote:
>
> On Thu, Feb 22, 2024 at 04:01:34PM +0530, shveta malik wrote:
> > On Thu, Feb 22, 2024 at 3:44 PM Bertrand Drouvot
> > <bertranddrouvot.pg@gmail.com> wrote:
> > >
> > > Hi,
> > >
> > > Thanks!
> > >
> > > Some random comments about v92_001 (Sorry if it has already been discussed
> > > up-thread):
> >
> > Thanks for the feedback. The patch is pushed 15 minutes back.
>
> Yeah, saw that after I send the comments ;-)
>
There is a BF failure. See
https://buildfarm.postgresql.org/cgi-bin/show_log.pl?nm=prion&dt=2024-02-22%2010%3A13%3A03.
The initial analysis suggests that for some reason, the primary went
down after the slot sync worker was invoked the first time. See the
below in the primary's LOG:
2024-02-22 10:59:56.896 UTC [2721639:29] standby1_slotsync worker LOG:
00000: statement: SELECT slot_name, plugin, confirmed_flush_lsn,
restart_lsn, catalog_xmin, two_phase, failover, database,
conflict_reason FROM pg_catalog.pg_replication_slots WHERE failover
and NOT temporary
2024-02-22 10:59:56.896 UTC [2721639:30] standby1_slotsync worker
LOCATION: exec_simple_query, postgres.c:1070
2024-02-22 11:00:26.967 UTC [2721639:31] standby1_slotsync worker LOG:
00000: statement: SELECT slot_name, plugin, confirmed_flush_lsn,
restart_lsn, catalog_xmin, two_phase, failover, database,
conflict_reason FROM pg_catalog.pg_replication_slots WHERE failover
and NOT temporary
2024-02-22 11:00:26.967 UTC [2721639:32] standby1_slotsync worker
LOCATION: exec_simple_query, postgres.c:1070
2024-02-22 11:00:35.908 UTC [2721435:309] LOG: 00000: received
immediate shutdown request
2024-02-22 11:00:35.908 UTC [2721435:310] LOCATION:
process_pm_shutdown_request, postmaster.c:2859
2024-02-22 11:00:35.911 UTC [2721435:311] LOG: 00000: database system
is shut down
2024-02-22 11:00:35.911 UTC [2721435:312] LOCATION: UnlinkLockFiles,
miscinit.c:1138
--
With Regards,