Re: Serial key mismatch in master and slave, while using slony - Mailing list pgsql-general

From Vick Khera
Subject Re: Serial key mismatch in master and slave, while using slony
Date
Msg-id AANLkTin8P5C=i_=9EQMOBoyO=H0qTrhL_pzVWu=P8e1t@mail.gmail.com
Whole thread Raw
In response to Serial key mismatch in master and slave, while using slony  ("Vishnu S." <vishnu.s@nestgroup.net>)
List pgsql-general
On Sat, Dec 18, 2010 at 7:12 AM, Vishnu S. <vishnu.s@nestgroup.net> wrote:
> I am using Slony-I slony-I-2.0.2 in windows .I have a master and a slave
> machine. The replication is working fine. When the master switches to slave
> , there exists a serial key mismatch in master and slave machines. So
> insertion fails in the slave machines. I am using the failover command to
> switch the slave to master.  Now the error message shown is  ‘Duplicate key
> violation’. On selecting the next value of the serial key the value shown is
> different from the actual value. Ie the shown value is very much less than
> the number of records in the table.

Why failover?  Is the master dead?

Are you syncing your sequences?  Is the duplicate a result of trying
to insert the primary key based on some sequence?  Clearly some data
is not fully synchronized when you did your failover.

Also, there is a whole mailing list dedicated to slony replication.
Take your question over there for best reach of people who can help
you.

pgsql-general by date:

Previous
From: "Mark Watson"
Date:
Subject: Re: Copy From suggestion
Next
From: Jorge Godoy
Date:
Subject: Re: Copy From suggestion