Re: problem with serial data type and access - Mailing list pgsql-general

From Adrian Klaver
Subject Re: problem with serial data type and access
Date
Msg-id 200805151816.21479.aklaver@comcast.net
Whole thread Raw
In response to Re: problem with serial data type and access  (Ottavio Campana <ottavio@campana.vi.it>)
Responses Re: problem with serial data type and access  (Ottavio Campana <ottavio@campana.vi.it>)
List pgsql-general
On Thursday 15 May 2008 9:14 am, Ottavio Campana wrote:
> Scott Marlowe ha scritto:
> > On Thu, May 15, 2008 at 7:54 AM, Ottavio Campana <ottavio@campana.vi.it>
wrote:
> >> I know it's not fully IT with the list, but maybe somebody can help me.
> >>
> >> I'm dealing with this scenario: access 97 is connected through odbc to a
> >> postgresql server. All tables are saved in postgresql and access is used
> >> only to generated the program interface.
> >>
> >> Everything works fines, but I'm having problems with the serial data
> >> type. I know a serial is an integer having as default the next value of
> >> a sequence. Since it is an integer, access does not recognize it as an
> >> autoincrement value, and it asks for is value.
> >>
> >> Did anyone of you already have this problem?
> >
> > Can you feed it a value of DEFAULT???
>
> I'd like to, but I don't think I could do it.
>
> The fact is that the serial data type is in pratice an integer, and when
> I also try to connect with pgadminIII I see an integer data type and not
> a serial. I think that since it sees an integer, it does not understand
> that it is a serial, and access does not recognize it as autoincrement.
>
> I'm stuck at this point...
Did you mark this field as the primary key when you linked the table?

--
Adrian Klaver
aklaver@comcast.net

pgsql-general by date:

Previous
From: "D. Dante Lorenso"
Date:
Subject: Re: PostgreSQL executing my function too many times during query
Next
From: Vitaliyi
Date:
Subject: SSL auth problem