Re: Reset oid , starting value=1 - Mailing list pgsql-general

From Martijn van Oosterhout
Subject Re: Reset oid , starting value=1
Date
Msg-id 20031209111803.GC10518@svana.org
Whole thread Raw
In response to Reset oid , starting value=1  ("Gellert, Andre" <AGellert@ElectronicPartner.de>)
List pgsql-general
The only way to reset oids is to destroy the entire data directory and
initdb again. In recent versions you can create tables without oids, thus
reducing their usage.

Hope this helps,

On Tue, Dec 09, 2003 at 11:22:15AM +0100, Gellert, Andre wrote:
> Hello,
> i have a bug in a php application based on postgres 7.2.2 , which cannot
> handle oid's greater than
> 2147483647 .
> So I have to reset the used oids to start from 1 again, so that we have more
> time to correct this bug, I tried to delete dropdb, createdb and read back
> the data, but the oids are not reseted , they start at the high values.
> How can i reset this oid-starting from value ?
> Are OIDs used once per postgres-installation (so they are unique over all
> databases, seem to be that way) , or are they only counted up in the current
> database ?
> There must be a global value which sets the last oid, i need to set this to
> "1" or to fill up from 1 , so i have no oids >= 2147483647 for the near
> future.. how can i do this ? Fixing the mentioned above will take more time.
>
> What i am looking for is a vacuumdb -a --forgetthoseoids ;-) , but I cannot
> find infos about that.
>
> bye,
> Andre Gellert
>
> ---------------------------(end of broadcast)---------------------------
> TIP 8: explain analyze is your friend

--
Martijn van Oosterhout   <kleptog@svana.org>   http://svana.org/kleptog/
> (... have gone from d-i being barely usable even by its developers
> anywhere, to being about 20% done. Sweet. And the last 80% usually takes
> 20% of the time, too, right?) -- Anthony Towns, debian-devel-announce

Attachment

pgsql-general by date:

Previous
From: Martin Hart
Date:
Subject: Casting Point to Text
Next
From: "Gellert, Andre"
Date:
Subject: Re: Reset oid , starting value=1