On Monday, March 9, 2026 11:17 AM Kuroda, Hayato/黒田 隼人 <kuroda.hayato@fujitsu.com> wrote:
> Few comments.
Thanks for the comments.
>
> 03.
> Can we describe needed privileges? IIUC, initial sync needs the UPDATE
> privilege, additionally periodic synch needs SELECT privilege.
I could not find existing doc for the privilege required for table sync or
sequence sync, so I think we can consider that as a separate patch.
>
> 04.
> ```
> + long sleep_ms = SEQSYNC_MIN_SLEEP_MS;
> ```
>
> This is used in the for loop, make it the loop-specific variable.
This value should survive across sync loop as it's dynamically
adjusted in the loop.
Other comments have been addressed in latest version.
Best Regards,
Hou zj