Hi,
On Tue, 27 Aug 2002 16:45:49 +0200
"joek hondius" <jhondius@rem.nl> wrote:
> Hi all,
> While testing i found this unexpected limit:
> There seems to be a hard 63 postmaster.exe backends limit to cygwin.
(snip)
> The questions:
> Is it true that cygwin cannot spawn more the 63 children?
Yes.
> Is this known?
Yes.
> Does someone have a good idea to work around this limit?
Cygwin B20 has no limitation about this(I succeed with 128 connections).
But I don't know whether latest PostgreSQL work on Cygwin B20(Probably
not).
---
Yutaka tanida<yutaka@hi-net.zaq.ne.jp>