Re: Synchronizing slots from primary to standby - Mailing list pgsql-hackers

From Bertrand Drouvot
Subject Re: Synchronizing slots from primary to standby
Date
Msg-id Zg91c+sQFf8xuMZ9@ip-10-97-1-34.eu-west-3.compute.internal
Whole thread Raw
In response to Re: Synchronizing slots from primary to standby  (shveta malik <shveta.malik@gmail.com>)
Responses Re: Synchronizing slots from primary to standby
List pgsql-hackers
Hi,

On Thu, Apr 04, 2024 at 05:31:45PM +0530, shveta malik wrote:
> On Thu, Apr 4, 2024 at 2:59 PM shveta malik <shveta.malik@gmail.com> wrote:
> >
> >
> > Prior to commit 2ec005b, this check was okay, as we did not expect
> > restart_lsn of the synced slot to be ahead of remote since we were
> > directly copying the lsns. But now when we use 'advance' to do logical
> > decoding on standby, there is a possibility that restart lsn of the
> > synced slot is ahead of remote slot, if there are running txns records
> > found after reaching consistent-point while consuming WALs from
> > restart_lsn till confirmed_lsn. In such a case, slot-sync's advance
> > may end up serializing snapshots and setting restart_lsn to the
> > serialized snapshot point, ahead of remote one.
> >
> > Fix:
> > The sanity check needs to be corrected. Attached a patch to address the issue.
> 

Thanks for reporting, explaining the issue and providing a patch.

Regarding the patch:

1 ===

+        * Attempt to sync lsns and xmins only if remote slot is ahead of local

s/lsns/LSNs/?

2 ===

+                       if (slot->data.confirmed_flush != remote_slot->confirmed_lsn)
+                               elog(LOG,
+                                        "could not synchronize local slot \"%s\" LSN(%X/%X)"
+                                        " to remote slot's LSN(%X/%X) ",
+                                        remote_slot->name,
+                                        LSN_FORMAT_ARGS(slot->data.confirmed_flush),
+                                        LSN_FORMAT_ARGS(remote_slot->confirmed_lsn));

I don't think that the message is correct here. Unless I am missing something
there is nothing in the following code path that would prevent the slot to be
sync during this cycle. 

Regards,

-- 
Bertrand Drouvot
PostgreSQL Contributors Team
RDS Open Source Databases