Thanks Heikki.
On Tue, Jul 10, 2018 at 6:47 PM, Heikki Linnakangas <hlinnaka@iki.fi> wrote:
> On 10/05/18 11:58, Ashutosh Bapat wrote:
>>
>> Hi,
>> I was investigating the cases when the system attributes are accessed
>> beyond the scans. After investigating set_plan_references(), I thought
>> that we never access system attributes beyond scans. This lead me to
>> assume that EEOP_INNER/OUTER_SYSVAR are not needed since we do not
>> access system attributes from an inner or outer slot. I removed the
>> defintions and code using those and ran regression. All the tests
>> passed. So, I was about to conclude that my assumption is correct. But
>> then looking at TriggerEnabled() I realised that we also (ab?)use
>> INNER/OUTER Vars for OLD/NEW tuples for trigger condition. If the WHEN
>> condition in CREATE TRIGGER command refers to a system attribute, we
>> will end up having INNER/OUTER var refering a system attribute, thus
>> exercising code for EEOP_INNER/OUTER_SYSVAR.
>>
>> Here's patch containing a testcase exercizing that code using
>> EEOP_INNER/OUTER_SYSVAR.
>
>
> Pushed with some small changes. Thanks!
>
> - Heikki
--
Best Wishes,
Ashutosh Bapat
EnterpriseDB Corporation
The Postgres Database Company