On Mon, May 16, 2022 at 9:18 PM Bruce Momjian <bruce@momjian.us> wrote:
>
> Newer wording:
>
> Improve validation of UTF-8 text (even if only ASCII) by processing
> 16 bytes at a time (John Naylor)
Thanks! I also think Heikki should be mentioned as a coauthor here --
the ASCII coding was his work in large part.
--
John Naylor
EDB: http://www.enterprisedb.com
From:
Amit Kapila Date: Subject:
Re: [BUG] Logical replication failure "ERROR: could not map filenode "base/13237/442428" to relation OID" with catalog modifying txns