This is a good question.  I am not sure what an appropriate handling would be.  My first test of '-infinity' (which
resultedin a raised error) was with an ado recordset.  Since you are questioning what is appropriate I thought that I
shouldtry a few different client front ends to see how they treated (+/-)infinity: 

Client   |   -infinity       | + infinity
ADO      | <error>           |9999-12-31 23:59:59|
Access/LT|1899-11-30 00:00:00|9999-12-31 23:59:59|
OOB(ODBC)|0001-01-03 00:00:00|9999-12-31 23:59:59|

ADO = ado recordset created in VB
Access/LT = a linked tabled in MS-Access (probably DAO/ODBC?)
OOB(ODBC) = Open Office.org Base ODBC connection to the Database.

Having done further tests, it seems that the error must be a bug with ADO since other clients have not a problem with
making-infinity equal to the smallest time stamp that their respective data type can display.  In my case, I do not
reallycare about what time stamp values are displayed by the clients for (+/-) infinity since I use these values as an
impliedNULL value for time stamps.  Unfortunately, ADO is broken and can't display any value for -infinity. 

> How do you think the driver should treat -infinity ?

It seems that it already handles it correctly. I was mistaken in thinking that the translation of (+/-) infinity was
handledby ODBC. :o) 