On Wed, Apr 08, 2020 at 11:57:08AM -0400, Robert Haas wrote:
> On Wed, Apr 8, 2020 at 10:25 AM Mahendra Singh Thalor
> <mahi6run@gmail.com> wrote:
> > I think, Tushar point is that either we should allow both
> > vacuum(parallel 0, full 1) and vacuum(parallel 1, full 0) or in the
> > both cases, we should through error.
>
> Oh, yeah, good point. Somebody must not've been careful enough with
> the options-checking code.
Actually I think someone was too careful.
From 9256cdb0a77fb33194727e265a346407921055ef Mon Sep 17 00:00:00 2001
From: Justin Pryzby <pryzbyj@telsasoft.com>
Date: Wed, 8 Apr 2020 11:38:36 -0500
Subject: [PATCH v1] parallel vacuum: options check to use same test as in
vacuumlazy.c
---
src/backend/commands/vacuum.c | 4 +---
1 file changed, 1 insertion(+), 3 deletions(-)
diff --git a/src/backend/commands/vacuum.c b/src/backend/commands/vacuum.c
index 351d5215a9..660c854d49 100644
--- a/src/backend/commands/vacuum.c
+++ b/src/backend/commands/vacuum.c
@@ -104,7 +104,6 @@ ExecVacuum(ParseState *pstate, VacuumStmt *vacstmt, bool isTopLevel)
bool freeze = false;
bool full = false;
bool disable_page_skipping = false;
- bool parallel_option = false;
ListCell *lc;
/* Set default value */
@@ -145,7 +144,6 @@ ExecVacuum(ParseState *pstate, VacuumStmt *vacstmt, bool isTopLevel)
params.truncate = get_vacopt_ternary_value(opt);
else if (strcmp(opt->defname, "parallel") == 0)
{
- parallel_option = true;
if (opt->arg == NULL)
{
ereport(ERROR,
@@ -199,7 +197,7 @@ ExecVacuum(ParseState *pstate, VacuumStmt *vacstmt, bool isTopLevel)
!(params.options & (VACOPT_FULL | VACOPT_FREEZE)));
Assert(!(params.options & VACOPT_SKIPTOAST));
- if ((params.options & VACOPT_FULL) && parallel_option)
+ if ((params.options & VACOPT_FULL) && params.nworkers > 0)
ereport(ERROR,
(errcode(ERRCODE_FEATURE_NOT_SUPPORTED),
errmsg("cannot specify both FULL and PARALLEL options")));
--