Re: Peter Eisentraut 2019-01-16 <92bfdfdf-4164-aec5-4e32-c26e67821c38@2ndquadrant.com>
> > Why don't we start the logging collector before opening the sockets?
>
> Specifically, something like the attached.
>
> This keeps the dynamic module loading before the logging collector
> start, so we see those error messages on stderr, but then the setting up
> of the sockets would get logged.
This works nicely, so +1.
I'm attaching your patch as 0001 and my rebased one on top of it as
0002.