Robert Haas wrote:
> On Mon, Sep 28, 2015 at 10:48 PM, Jim Nasby <Jim.Nasby@bluetreble.com> wrote:
> > Maybe I'm confused, but I thought the whole purpose of this was to get rid
> > of the risk associated with that calculation in favor of explicit truncation
> > boundaries in the WAL log.
>
> Yes. But if the master hasn't been updated yet, then we still need to
> do something based on a calculation.
Right.
> > Even if that's not the case, ISTM that being big and in your face about a
> > potential data corruption bug is a good thing, as long as the DBA has a way
> > to "hit the snooze button".
>
> Panicking the standby because the master hasn't been updated does not
> seem like a good thing to me in any way.
If we had a way to force the master to upgrade, I think it would be good
because we have a mechanism to get rid of the legacy truncation code;
but as I said several messages ago this doesn't actually work which is
why I dropped the idea of panicking.
--
Álvaro Herrera http://www.2ndQuadrant.com/
PostgreSQL Development, 24x7 Support, Remote DBA, Training & Services