> Horak Daniel <horak@mmp.plzen-city.cz> writes:
> > I have tested my solution a bit more and I have to say that reusing a
> > semaphore by a new backend works OK. But it is not possible for a newly
> > created backend to use a semaphore allocated by postmaster (it freezes on
> > test if the semaphore with given key already exists - done with
> > semId=semget(semKey, 0, 0) in function IpcSemaphoreCreate() in
> > storage/ipc/ipc.c ). Why it is, I don't know, but it seems that my solution
> > uses the ipc library in the right way.
>
> It seems that you have found a bug in the cygipc library. I suggest
> reporting it to the author of same...
Yes, but can we expect all NT sites to get the patch before using
PostgreSQL? Is there a workaround we can implement?
-- Bruce Momjian | http://www.op.net/~candle maillist@candle.pha.pa.us | (610)
853-3000+ If your life is a hard drive, | 830 Blythe Avenue + Christ can be your backup. | Drexel Hill,
Pennsylvania19026