Re: Offline enabling/disabling of data checksums - Mailing list pgsql-hackers

From Michael Banck
Subject Re: Offline enabling/disabling of data checksums
Date
Msg-id 1552578874.9697.6.camel@credativ.de
Whole thread Raw
In response to Re: Offline enabling/disabling of data checksums  (Magnus Hagander <magnus@hagander.net>)
Responses Re: Offline enabling/disabling of data checksums
List pgsql-hackers
Hi,

Am Donnerstag, den 14.03.2019, 15:32 +0100 schrieb Magnus Hagander:
> On Thu, Mar 14, 2019 at 3:28 PM Christoph Berg <myon@debian.org> wrote:
> > Re: Magnus Hagander 2019-03-14 <CABUevEx7QZLOjWDvwTdm1VM+mjsDm7=ZmB8qck7nDmcHEY5O5g@mail.gmail.com>
> > > Are you suggesting we should support running with a master with checksums
> > > on and a standby with checksums off in the same cluster? That seems.. Very
> > > fragile.
> > 
> > The case "shut down master and standby, run pg_checksums on both, and
> > start them again" should be supported. That seems safe to do, and a
> > real-world use case.
> 
> I can agree with that, if we can declare it safe. You might need some
> way to ensure it was shut down cleanly on both sides, I'm guessing. 
> 
> > Changing the system id to a random number would complicate this.
> > 
> > (Horrible idea: maybe just adding 1 (= checksum version) to the system
> > id would work?)
> 
> Or any other way of changing the systemid in a predictable way would
> also work, right? As long as it's done the same on both sides. And
> that way it would look different to any system that *doesn't* know
> what it means, which is probably a good thing.

If we change the system identifier, we'll have to reset the WAL as well
or otherwise we'll get "PANIC:  could not locate a valid checkpoint
record" on startup.  So even if we do it predictably on both primary and
standby I guess the standby would need to be re-cloned?

So I think an option that skips that for people who know what they are
doing with the streaming replication setup would be required, should we
decide to bump the system identifier.


Michael

-- 
Michael Banck
Projektleiter / Senior Berater
Tel.: +49 2166 9901-171
Fax:  +49 2166 9901-100
Email: michael.banck@credativ.de

credativ GmbH, HRB Mönchengladbach 12080
USt-ID-Nummer: DE204566209
Trompeterallee 108, 41189 Mönchengladbach
Geschäftsführung: Dr. Michael Meskes, Jörg Folz, Sascha Heuer

Unser Umgang mit personenbezogenen Daten unterliegt
folgenden Bestimmungen: https://www.credativ.de/datenschutz


pgsql-hackers by date:

Previous
From: Julien Rouhaud
Date:
Subject: Re: Sparse bit set data structure
Next
From: Robert Haas
Date:
Subject: Re: ATTACH/DETACH PARTITION CONCURRENTLY