Hi,
after a power failure we are getting these errors now:
2002-03-29 01:10:01 DEBUG: checkpoint record is at 16/FC033344
2002-03-29 01:10:01 DEBUG: redo record is at 16/FC033344; undo record is at
0/0; shutdown TRUE
2002-03-29 01:10:01 DEBUG: next transaction id: 73731718; next oid: 6745356
2002-03-29 01:10:01 DEBUG: database system was not properly shut down;
automatic recovery in progress
2002-03-29 01:10:01 DEBUG: redo starts at 16/FC033384
2002-03-29 01:10:01 DEBUG: ReadRecord: invalid magic number 0000 in log
file 22, segment 252, offset 1597440
2002-03-29 01:10:01 DEBUG: redo done at 16/FC185054
2002-03-29 01:10:02 FATAL 1: The database system is starting up
2002-03-29 01:10:02 FATAL 1: The database system is starting up
2002-03-29 01:10:04 DEBUG: recycled transaction log file 00000016000000FA
2002-03-29 01:10:04 DEBUG: recycled transaction log file 00000016000000FB
2002-03-29 01:10:04 DEBUG: database system is ready
2002-03-29 01:10:10 FATAL 2: PageAddItem: corrupted page pointers: lower =
8226, upper = 27747, special = 3183
2002-03-29 01:10:10 DEBUG: server process (pid 2742) exited with exit code
2
2002-03-29 01:10:10 DEBUG: terminating any other active server processes
What exactly does PageAddItem talk about here and how do I fix it?
Thanks,
Bjoern